CONVENTIONAL FIRE ALARM EQUIPMENTS



Illustration Of Fire Alarm Fittings

   
 CONVENTIONAL PANEL CCP Series from 1 zone up to 100 zone.
  MAIN FEATURES  

Control key switch.

Mains healthy indicator.

Continuous alarm signal.
Built-in battery.
Polarity protection for battery.
Push buttons for Evacuate, Reset and Alarm silence.
Monitored alarm circuits for both open & short circuit.
Individual sounder circuits for zones (optional).
Indicators for Charger fault & Battery fault.
All controls are on front fascia.
Knockouts on top and bottom sides for easy installation.
  SPECIFICATIONS  
Main supply - 240 V AC +/- 10%,50/60 Hz
Battery supply - 24 V DC (Sealed Lead Acid).
Glass fuse protection - Main supply Charging voltage, Sounder circuit, Reserve battery connection.
Auxiliary realy contacts - 30 V DC, lA, NO/Ne.
 REPEATER PANEL CRP Series from 4 zone up to 64 zone
  MAIN FEATURES

Green LED for Power on indication

Red LET for Common Fire indication

Yellow LED for Common Fault indication

Red LED for Zonal Fire indication

 
 GAS EXTINGUISHING CONTROL CEP Series up to 8 firing area.
  MAIN FEATURES
Control key switch.
Indicators on front fascia.
Built-in battery.
Monitored alarm circuits for both open & short circuit.
Indicators for Charge fault & Battery fault.
All controls are on front fascia.
Manual operating switch on front fascia.
2 monitored detection on Zones.
Monitored gas release.
Knockouts on top and bottom sides for easy installation.
Resease timer.
Conventional Detectors                                                                                       Top
           

Accessories                                                                                                            Top

           

Smoke Detectors

For fast burning, high energy fires.
Petrochemical or solvent stores
Electrical switch rooms

A mixture of optical and ionization sensors can be used to ensure coverage in areas of high value, like computer rooms.

Heat Detectors
Heat detectors are used where the environment is subject to constant levels of smoke or dirt.
Loading bays
Boiler rooms
Kitchens and laundries
Plant rooms

Rate of Rise Detector
Has fixed temp operation, but also looks for sudden rises in temperature give faster reaction than standard fixed temp detector, Areas deemed unsuitable for smoke detection due to dust or other contamination.

Flame detection
This is particularly suited in applications where flame can be expected to develop initially rather than smoke, due to the nature of the combustible materials such as camera films, video/audio/computer tapes...
Large production facilities
Warehouses
Ceiling voids, above false ceilings
Shopping malls
Aircraft hangers

Stand-alone Detector
Stand-alone detector was designed with precise microprocessor control integrating both carbon monoxide detection. It could be one of the best Standalone detectors available in the market. It's perfectly suitable for installation in all environment especially in the kitchen, garage, factory etc.

 
 
 
 
 
 

    