 |
Intelligent Optical Smoke Detector
- 8 Bit intelligent processor with A/D converter
- Built in algorithm maps for false alarm rejection
- Electronically addressable
- Aesthetically pleasing low profile design
- Twin LED for 360° vision
- With Remote indicator output
- Sensitivity adjustable via hand held programming tool
- Removable optical chamber for easy cleaning and maintenance
Technical Specifications
- Operating Voltage: 24VDC Loop
- Operating Current: Standby Current:0.8mA ; Alarm Current: 2mA (5mA for RI)
- Operating Environment: Temperature : -10~+50°C ; Relative Humidity : 95%
- Dimensions: 100mm, Height 50mm
|
 |
Intelligent Dual Heat Detector
- Aesthetically pleasing low profile design
- Fixed Temperature and Rate of Rise Heat Detection
- 8 Bit intelligent processor with A/D converter
- Electronically addressable
- With Remote Indicator output
- Twin LED for 360° vision
Technical Specifications
- Operating Voltage: 24VDC Loop
- Operating Current: Standby Current:0.8mA ; Alarm Current: 2mA (5mA for RI)
- Operating Environment: Temperature : -10~+50°C ; Relative Humidity : 95%
- Dimensions: 100mm, Height 50mm
|
 |
Intelligent Multi Sensor
- Combining all the features of the D-A411 Optical and the D-A412 Dual Heat Detector to provide the ultimate cover for life safety systems
- Ideal alternative to ionization detectors
- Adjustable smoke detection sensitivity by handheld programmer
Technical Specifications
- Operating Voltage: 24VDC Loop
- Operating Current: Standby Current:0.6mA ; Alarm Current: 1.8mA
- Operating Environment: Temperature : -10~+50°C ; Relative Humidity : 95%
- Field Programmable Sensitivity: 0.1dB/m~0.56dB/m-3 levels
- Dimensions: 100mm, Height 50mm
|
 |
Intelligent Ultraviolet Flame Detector
- Aesthetically pleasing low profile design
- Sensitive Ultraviolet sensor that detects the UV rays produced by a Flame
- Dust / corrosion / humidity resistant
- Electronically addressable
- Standard calibration which is set to detect a 3cm flame at 6 metres
- Effective range of 12 metres
Technical Specifications
- Operating Voltage: 24VDC Loop
- Operating Current: Standby Current:2mA ; Alarm Current: 2.5mA
- Operating Environment: Temperature : -10~+50°C ; Relative Humidity : 95%
- Direction Angle: 80°
- Dimensions: 100mm, Height 41mm
|
 |
Standard Detector Base
- Base for the fixing of detectors
- Non-electronic component
- Common base for D-A411 / 2 / 3 / 4
|
 |
Intelligent Reflective Beam Detector
- Range of 8 - 1000 metres
- 2 selectable levels of sensitivity adjustment
- Ideal for Atriums, Warehouses, Shopping Centers, Airport Terminals, etc.
- Simple and cost effective installation of transmitter and reflective "honey comb" mirror
- Quick and easy to set up and aligns with visual green LED indication that flashes faster to slower which is subject to signal strength. Replacing the cover and the detector will self calibrate to the required level
Technical Specifications
- Operating Voltage:24 VDC Loop, 24 VDC power supply
- Operating Current ( power supply):Power current:Commission current: 20mA
Standby current: 8mA; Alarm current: 12mA Loop Powered: Standby current0.6mA; Alarm current: 2mA
- Detection Range: Length from 8 to 100 meters, width 7 meters in both the sides
- Wiring : Non-polarized two-core 24 VDC
- Operating Environment: Temperature: -10~+50°C ; Relative Humidity: 95%
- Dimensions: 206 mm * 95 mm * 95 mm
|
 |
Addressable Combustible Gas Detector
- Available for LPG, Natural Gas and Coal Gas ( please specify at time of order )
- Built - in relay contacts for control of Gas Valves / Extract, etc.
- Built - in sounder with 2 stage alarm
- Manual reset and control (on/off) of relay contacts
- Electronically addressable
- Wall-mount (LPG) or ceiling mount (Natural Gas and Coal Gas)
Technical Specifications
- Operating Voltage:24 VDC Loop, 24 VDC power supply
- Operating Consumption ( power supply):1.5 Watt
- Alarm level:Pre-alarm: 12% LEL ; Urgent alarm: 23% LEL
- Output : K1/K2, N/O contact, 3A/220VAC, active when pre-alarm V1 / V2, 24VDC Pulse
- Operating Environment : Temperature: -10~+50°C ; Relative Humidity: 95%
- Wiring : Non-polarized 2-core for loop ; Non-polarized 2-core for 24VDC power supply
- Dimensions: 121 mm * 87 mm * 57 mm
|
 |
Addressable Manual Call Point
- Addressable Manual Call Point (MCP) with re-settable (non breakable) glass
- Additional volt free contacts for local interfacing (i.e PTZ camera preset)
- Two parts plug-in construction with base mounted termination allows for easy installation and connection
- MCP can be addressed and plugged in to base at the time of commissioning
- Electronically addressable
- Suitable for semi-flush and surface mount installation
Technical Specifications
- Operating Voltage:24 VDC Loop
- Operating Current:Standy current 0.6mA; Alarm current 1.8mA
- N/O Output Contact:Rating 60VDC, 0.1A
- Contact Resistance : 100m Ω
- Operating Environment : Temperature: -10~+50°C ; Relative Humidity: 95%
- Dimensions: 90 mm * 122 mm * 48.5 mm
|