CONVENTIONAL FIRE ALARM DEVICES

Innovative Optical Smoke Detector

  • Intelligent drift compensation
  • Algorithm maps for faster response and false alarm rejection
  • Sensing chamber for exceptional dust proof ability and LED for 360’ vision
  • Built in remote indicator output
  • Unique low profile design
  • EN54 compliance

Technical Specifications

  1. Standard: EN54-part 7
  2. Operating Voltage: 24 VDC
  3. Operating Current: Standby Current: 0.06mA; Alarm Current: 30mA
  4. Operating Environment: Temperature: -10~ +50’C; Relative Humidity: 95%
  5. Field Programmable Sensitivity: 0.102dB/m ~ 0.316dB/m-3 levels
  6. Dimensions: Diameter 100mm, Height 44.5mm

Innovative Conventional Dual Heat Detector

  • Twin LED for 360’ vision
  • Combined fixed temperature and rate of rise heat detection
  • Built in remote indicator design
  • EN54 compliance

Technical Specifications

  1. Standard: EN54-part 5
  2. Operating Voltage: 24 VDC
  3. Operating Current: Standby Current: 0.06mA; Alarm Current: 55mA
  4. Operating Environment: Temperature: -10~ +50’C; Relative Humidity: 95%
  5. Detector Class: A1R, A2R, BR, A1S, A2S, BS
  6. Dimensions: Diameter 100mm, Height 44.5mm

Innovative Multi Sensor

  • LED for 360’ vision
  • Combined all the features of the D-C401C Optical and the D-C402C Heat detector
  • Sensing chamber for exceptional dust proof ability
  • Ideal alternative to Ionization detector
  • Low profile design

Technical Specifications

  1. Standard: EN54-part 5, part 6 and part 7
  2. Operating Voltage: 24 VDC
  3. Operating Current: Standby Current: 0.06mA; Alarm Current: 30mA
  4. Operating Environment: Temperature: -10~ +50’C; Relative Humidity: 95%
  5. Field Programmable Sensitivity: 0.102dB/m-3 levels
  6. Dimensions: Diameter 100mm, Height 44.5mm

Diode Base

  • Diode base for DC range of conventional detectors
  • For use with DB-CA Active End of Line

Active End of Line

  • Active End of Line for conventional fire detection zones
  • It can be used as conventional detector base or work independent with a cover
  • Provides detector removal indication while still enabling alarms down stream of the missing device to be detected
  • Compatible with all SHIELD conventional panels
  • Compatible with addressable zone interface AI-515

Innovative Manual Call Point

  • Semi-flush or surface mount installation
  • Optional back-box for surface mount
  • Pleasing style design

Technical Specifications

  1. Protection Rating: IP55
  2. Operating Voltage: 24 VDC
  3. Operating Current: Standby Current:0; Alarm Current: 30mA
  4. Operating Environment: Temperature: -10~ +50’C; Relative Humidity: 95%
  5. Contact Resistance: 100mΩ
  6. Application: Indoor use
  7. Dimensions: 87 * 87 * 58mm, Surface Mount ; 87 * 87 * 23.5mm, Recess Mount