Innovative Optical Smoke Detector
- Intelligent drift compensation
- Algorithm maps for faster response and false alarm rejection
- Sensing chamber for exceptional dust proof ability and LED for 360’ vision
- Built in remote indicator output
- Unique low profile design
- EN54 compliance
Technical Specifications
- Standard: EN54-part 7
- Operating Voltage: 24 VDC
- Operating Current: Standby Current: 0.06mA; Alarm Current: 30mA
- Operating Environment: Temperature: -10~ +50’C; Relative Humidity: 95%
- Field Programmable Sensitivity: 0.102dB/m ~ 0.316dB/m-3 levels
- Dimensions: Diameter 100mm, Height 44.5mm
|
 |
Innovative Conventional Dual Heat Detector
- Twin LED for 360’ vision
- Combined fixed temperature and rate of rise heat detection
- Built in remote indicator design
- EN54 compliance
Technical Specifications
- Standard: EN54-part 5
- Operating Voltage: 24 VDC
- Operating Current: Standby Current: 0.06mA; Alarm Current: 55mA
- Operating Environment: Temperature: -10~ +50’C; Relative Humidity: 95%
- Detector Class: A1R, A2R, BR, A1S, A2S, BS
- Dimensions: Diameter 100mm, Height 44.5mm
|
 |
Innovative Multi Sensor
- LED for 360’ vision
- Combined all the features of the D-C401C Optical and the D-C402C Heat detector
- Sensing chamber for exceptional dust proof ability
- Ideal alternative to Ionization detector
- Low profile design
Technical Specifications
- Standard: EN54-part 5, part 6 and part 7
- Operating Voltage: 24 VDC
- Operating Current: Standby Current: 0.06mA; Alarm Current: 30mA
- Operating Environment: Temperature: -10~ +50’C; Relative Humidity: 95%
- Field Programmable Sensitivity: 0.102dB/m-3 levels
- Dimensions: Diameter 100mm, Height 44.5mm
|
 |
Diode Base
- Diode base for DC range of conventional detectors
- For use with DB-CA Active End of Line
|
 |
Active End of Line
- Active End of Line for conventional fire detection zones
- It can be used as conventional detector base or work independent with a cover
- Provides detector removal indication while still enabling alarms down stream of the missing device to be detected
- Compatible with all SHIELD conventional panels
- Compatible with addressable zone interface AI-515
|
 |
Innovative Manual Call Point
- Semi-flush or surface mount installation
- Optional back-box for surface mount
- Pleasing style design
Technical Specifications
- Protection Rating: IP55
- Operating Voltage: 24 VDC
- Operating Current: Standby Current:0; Alarm Current: 30mA
- Operating Environment: Temperature: -10~ +50’C; Relative Humidity: 95%
- Contact Resistance: 100mΩ
- Application: Indoor use
- Dimensions: 87 * 87 * 58mm, Surface Mount ; 87 * 87 * 23.5mm, Recess Mount
|
 |
Weather Proof Box
- IP65 protective enclosure for manual call points
|